Senlim Terminals & Maritime

Ashore

Road, Rail & Pipeline

How the cargo leaves when it does not leave by sea.

Most of what we hold leaves by water, but a great deal leaves by road, by rail or down a pipe, and those three have nothing in common except that they all end at the same manifold.

Bottom loading with vapour recovery for road. Overhead gantries with folding access platforms for rail. A metered, pigged connection at the fence for pipeline.

Bottom
Road loading
With vapour return, not splash filling
Gantry
Rail
Overhead, with fall protection
Metered
Pipeline
Custody meters, proved on programme

Road loading is a booking, not a queue

Hauliers book a slot. The product, the quantity and the driver are known before the vehicle arrives, the bay is assigned, and the loading is automatic against the booked quantity.

It is faster for the haulier and it removes the commonest cause of a wrong delivery: a verbal instruction at the gate.

Pipeline interfaces

A pipeline moving more than one grade has an interface between batches. We track it, we cut it to the agreed rule, and the interface volume goes where the contract says it goes.

At a glance

ModeTypical parcelWhat governs it
Road tanker20–40 tonnesDriver booking, bottom loading, vapour return
Rail tank wagon60–90 tonnes eachRake booking, gantry access, brake isolation
PipelineContinuousBatch scheduling, interface tracking, meter proving

What we check, every time

  • Driver and vehicle checked against the booking at the gate.
  • Earthing and overfill protection proven before loading starts.
  • Vapour return connected on every volatile grade.
  • Rail access platforms lowered and fall protection in use.
  • Custody meters proved within their calibration period.

Tell us what needs holding

Tell us the product, the volume, the dates and the route. We will tell you what we can do, and what we cannot.